Coil Failure pt. 2: Current Flow & Crack Propagation
June 20th, 2011
The skin and proximity effects — as well as the “ring,” “slot,” and edge effects — lead to a nonuniform current distribution within a copper coil. Areas of high current density within this distribution are the primary candidates for localized hot spots, which can result in premature coil failure.